#23505

Paxxon 1500VA UPS with 4 standard wall power outlets

Reliable 1500VA battery back-up UPS with 4 wall power outlets, suitable to power and protect your electronic devices

Available from February

Key features

  • Reliable 1500VA UPS with built-in battery
  • Provides temporary battery power during power outage; prevents loss of data and damage to hardware
  • 4 wall power outlets with battery and surge protection to connect your computer, computer peripherals, networking equipment, flatscreen TV, home automation products or alarm system
  • Surge protected outputs to prevent damage from power surges, spikes and fluctuations
  • USB port and software to monitor the status of the UPS, sending alerts and automatic shutdown of your computer
  • AVR function to ensure stable 230V output voltage
  • Clear audible alerts when the power goes out, so you have time to save your files and shut down your computer
  • Built-in overload, discharge, and overcharge protection
  • Extended warranty of €20.000 on connected equipment*
  • *Check conditions on trust.com

Specifications

General
Height of main product (in mm) 320 mm
Width of main product (in mm) 182 mm
Depth of main product (in mm) 130 mm
Total weight 10000 g
Weight of main unit 10000 g
Connectivity
Cable detachable no
Cable length main cable 140 cm
Cables included USB-B to USB-A
Features
Audible alarm yes
Software yes
Management function (USB) yes
USB connection yes
Status display no
Protection
Protections child safety shutter, current-recoil, over-charge, over-cranking, over-current, over-discharge, over-heat, over-load, short-circuit
Auto Voltage Regulation yes
RFI-filter no
Surge protected AC outlets yes
Surge protected phone line no
Power
Battery capacity (Ah) 12 Ah
Battery voltage (V) 9 V
Number of power outlets 4
Battery charge time (hours) 8 hours
100% capacity runtime (seconds) 80 seconds
50% capacity runtime (minutes) 7 minutes
Number of batteries 2
Battery composition (Alkaline, Li-ion, etc.) Lead Acid
Power inlet connection Schuko (Type F)
Power outlet socket type Schuko, Type L
Input
Nominal input voltage 220-240Vac
Operating voltage range 162-290Vac
Output
Output power capacity (W) 900 W
Output voltage range nominal voltage
Output power capacity (VA) 1500 W
Frequency response UPS 50Hz +/- 1Hz
Waveform type simulated sine wave
Control
Indicators Battery, Battery empty, Charging, Overload, Power

Extra information

General Item number:
23505
EAN code:
8713439235050
Warranty:
1   year
Product weight (net):
10000 g
Package contents UPS unit USB cable User guide
System requirements - Grounded wall power connection - For software: Windows 10/8/7, USB port - 155MB of free hard disk space - Latest software downloadable from: - www.trust.com/23505/driver
;

Support

Download

Manuals


Select type

Software


Select your operating system (OS)
;

Frequently Asked Questions

Installation and configuration


How to install the UPS?

- First let the UPS charge overnight: plug it in, turn it on, and with no load attached, let it charge for at least 9 hours.
- When the UPS is fully charged, connect the equipment to the UPS. Make sure to not exceed 900W.


Where can I get software/drivers for my Trust product?

Software/drivers are available in the downloads section.

Where is the Mac-driver / software?

This particular product has been developed for use with the Windows operating systems only.

Therefore drivers or installation instructions for other operating systems such as Mac are not available.

Nor is in fact the use of this product in any way supported with other operating systems, which don't meet our product's specifications and requirements.


Usage


What is the Watt rating of my UPS?

Each model of UPS is capable of handling a predetermined amount of power draw. Always make sure that the wattage draw from your equipment plugged into the outlets does not exceed the Watt rating. The Watt rating of your UPS is 900W.


What do the LEDs and sounds mean?

- Green LED: This indicates that the UPS is operating normally on utility power from your wall socket.


- Yellow LED plus sound: This indicates that your UPS isn't operating on utility power from your wall socket. Check the wall power, and cabling.


- Red LED plus sound: This indicates an error, and can have 2 reasons:


1. The equipment connected to the UPS is drawing more power than the UPS can provide. Each model of UPS is capable of handling a predetermined amount of power draw. Verify that the wattage draw from your equipment plugged into the outlets does not exceed the Watt rating.

2. The battery is near the end of its useful life. It is a warning that the battery needs to be replaced. It does not necessarily mean that the battery is dead. The typical life span of the battery is 2-4 years depending on use and environment (temperature). Before replacing the battery, however, you should let the UPS charge overnight (leave it plugged in, turned on, and with no load attached). Then test the UPS. If the UPS fails the test and the unit is still in warranty (2 years from date of purchase), contact our support for further troubleshooting. If the unit is out of warranty, a replacement battery should be ordered from your local retailer.


Is it required to discharge the UPS regularly for maintenance?

Modern batteries do not require this, but is optional.

What backup time can I expect?

Backup time is highly dependent on what type of PC is connected.
The time mentioned on package/website is the maximum backup time.

Solving problems


What should I do if my device stops working?

Please check if the circuit breaker on the back of the device has tripped. If so, the button labeled “press to reset” should have sprung out. When this is the case, please turn off the UPS, disconnect all attached devices and press the button on the back. This will reset the circuit breaker.

After resetting the circuit breaker, please turn on the UPS to see if it works and reconnect the devices one by one.

In the event that the UPS won’t turn on after resetting the breaker, please contact our support team via the 'ask a question' option on the product page.


The battery is dead

If your UPS is still under warranty (the warranty term for UPS is 2 years), we suggest you to get in contact with your retailer and replace it under the proof of purchase.
If your UPS is no longer covered by warranty and you want to replace the battery, you can find a suitable battery in special stores or on the internet.

I measure a different output voltage than 220~230VAC

The UPS outputs a so called "stepped sine" voltage.
Some voltage meters misunderstand this and display a wrong voltage.
 
Note: Connected devices won't have any problem with this stepped sine voltage.

Where is your service center? Or where can I send my product to be repaired?

Unfortunately, we do not have service centers to repair products.
A defective product should be replaced by your point of purchase during the warranty period.


My product is faulty. What do I do?

We offer a 'return to retailer' warranty on our products. In case of a defect, you can return the product to your retailer with failure description, proof of purchase and all accessories. During the warranty period you will receive a replacement product from the retailer if available. For full warranty conditions you can consult: https://www.trust.com/support/warranty



Warranty

Warranty conditions
  • Trust offers a warranty to the original purchaser from an authorized retailer.
  • Your Trust product is guaranteed under the terms and conditions of this warranty against manufacturing defects for a period of one (1) year* from the date of original purchase, if purchased from an official retailer.
    • *In Europe, there is a statutory minimum warranty period of 2 years on every product we sell.
  • In case of defect, return the product to your retailer with failure description, valid proof of purchase and all accessories.
  • During the warranty period you will receive a replacement product from the retailer if available.
  • Warranty will be void in cases of opened products, physical damage, misuse, modification, repair by unauthorised persons, carelessness and using the product for other purpose than its intended use.
  • Exclusions of warranty:
    • Damage caused by accidents or disasters, such as fire, flood, earthquake, war, vandalism or theft.
    • Incompatibility with other hardware/software not defined as minimum system requirements.
    • Accessories such as batteries and fuses.
  • In no event shall the manufacturer be liable for any consequential or incidental damages, including any loss of business profits or any other commercial damages, arising out of the use of its product.

 


Ask a question to the helpdesk

Support

Please check our FAQs first, chances are you'll find the answer there.

Couldn't find the answer in the FAQs? Fill out the form below with as much information as possible and one of our help-desk staff will respond at the earliest opportunity. Our messages are answered in the order they are received.

After submitting the form a confirmation message will be displayed with your reference number. The confirmation will be send to your email address at the same time as well. If you have not received the confirmation message, please check your spam or junk mail folder. Otherwise, fill out the form again with your correct e-mail address.

Reason for contact

*

Message

*

Your profile

*
*
*
*

Product details

*
*

This form is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.


Register product

Login to register your Trust product(s)

Register product

*Prices stated by Trust are non-binding average recommended retail prices including VAT and are subject to change without prior notice.

;